Med. interna Méx ; 34(4): 517-521, jul.-ago. 2018. tab
Article in Spanish | LILACS | ID: biblio-984708

ABSTRACT

Resumen OBJETIVO Determinar si existe diferencia entre la medición de la presión arterial en el brazo con brazalete de tamaño adecuado para el paciente (circunferencia del brazo > 34 cm) vs medición de la presión arterial en el antebrazo con brazalete estándar (circunferencia de brazo 22-33 cm) en pacientes con circunferencia de brazo > 34 cm. MATERIAL Y MÉTODO Estudio prospectivo, observacional y transversal realizado de enero a junio de 2017. Se incluyeron pacientes de consulta externa del Hospital General de Mexicali con circunferencia del brazo > 34 cm. Se midió la presión arterial en el antebrazo con brazalete estándar, se realizó una segunda toma de la presión arterial en el brazo con brazalete para pacientes con diámetro de brazo mayor a 33 cm. RESULTADOS Se incluyeron 320 pacientes, 67% eran mujeres, con media de edad de 41 años, la circunferencia promedio del brazo fue de 38 cm. En hombres, la media fue de 35 años, con circunferencia promedio del brazo de 38 cm. La media de la presión sistólica en el antebrazo fue de 128.6 ± 12.5 vs 125.5 ± 13.6 mmHg en el brazo, con diferencia de 3.54 con valor p = 0.0007. La media de la presión arterial diastólica en el antebrazo fue de 83.42 ± 8.95 vs 79.21 ± 8.88 mmHg en el brazo, con diferencia entre ambos de 4.21, p ≤ 0.0001. CONCLUSIONES La obtención de la presión arterial en el antebrazo con un brazalete estándar en pacientes con circunferencia del brazo mayor a 34 cm cuando no se cuente con un brazalete apropiado proporcionará cifras similares a las obtenidas con un brazalete adecuado, con lecturas mayores, pero con diferencias por debajo de 5 mmHg.


Abstract OBJECTIVE To determine if there is a difference between measuring blood pressure in the arm with and adequate size bracelet for patients (arm circumference > 34 cm) vs measuring blood pressure in the forearm with a standard bracelet (arm circumference < 22-33 cm) in patients with arm circumference > 34 cm. MATERIAL AND METHOD A prospective, observational, cross-sectional study was done from January to June 2017. Sample: patients from external consult of Hospital General de Mexicali with arm circumference > 34 cm. Blood pressure was measured in the forearm of the patient with a standard bracelet, blood pressure was measured again in the arm with an adequate bracelet (for patients with an arm circumference > 33 cm). RESULTS 320 patients were included for this study, 67% were women, with an average age of 41 years, average arm circumference was of 38 cm. In men, the average age was 35 years with an average arm circumference of 38 cm. Average of the systolic pressure in the forearm was 128.6 ± 12.5 vs 125.5 ± 13.6 mmHg in the arm, with a difference of 3.54 with a p = 0.0007. The average of the diastolic pressure in the forearm was 83.42 ± 8.95 vs 79.21 ± 8.88 mmHg in the arm with a difference of 4.21, p ≤ 0.0001. CONCLUSIONS Measurement of blood pressure in the forearm with a standard bracelet in patients with an arm circumference > 34 cm when we don't have the adequate bracelet will give us similar values compared to the blood pressure in the arm with an adequate bracelet, with higher values but differences below 5 mmHg.

2.
Med. interna Méx ; 34(3): 486-489, may.-jun. 2018. graf
Article in Spanish | LILACS | ID: biblio-976091

ABSTRACT

Resumen La angina mesentérica es un síndrome causado por la inadecuada perfusión sanguínea por parte de los vasos mesentéricos, que resulta en isquemia y a la larga en gangrena de la pared intestinal. Aunque relativamente poco frecuente, es un padecimiento potencialmente mortal. Reportamos un caso de isquemia mesentérica que inició con plenitud, dolor posprandial temprano, distensión abdominal y pérdida de peso en un paciente previamente diagnosticado y tratado de linfoma de colon y adenocarcinoma prostático.


Abstract Mesenteric angina is a syndrome caused by inadequate perfusion from the mesenteric vessels, resulting in ischemia and eventually gut necrosis. Although relatively rare, it is a potential deadly condition. We report a case of mesenteric ischemia which began with bloating, postprandial pain and weight loss on a patient previously diagnosed and treated from colonic lymphoma and prostatic adenocarcinoma.